ANNEX IVActivity-specific monitoring methodologies related to installations (Article 20(2))

16.Determination of nitrous oxide (N2O) emissions from nitric acid, adipic acid, caprolactam, glyoxal and glyoxylic acid production as listed in Annex I to Directive 2003/87/EC

B.Determination of N2O emissions

B.3.Determination of flue gas flow

The operator shall use the methods for monitoring flue gas flow set out in Article 43(5) of this Regulation for measuring the flue gas flow for N2O emissions monitoring. For nitric acid production, the operator shall apply the method in accordance with point (a) of Article 43(5) unless it is technically not feasible. In that case and upon approval by the competent authority, the operator shall apply an alternative method, including by a mass balance methodology based on significant parameters such as ammonia input load, or determination of flow by continuous emissions flow measurement.

The flue gas flow shall be calculated in accordance with the following formula:

Vflue gas flow [Nm3/h] = Vair * (1 – O2,air)/(1 – O2,flue gas)

Where:

Vair

Total input air flow in Nm3/h at standard conditions;

O2,air

Volume fraction of O2 in dry air [= 0,2095];

O2,flue gas

Volume fraction of O2 in the flue gas.

The Vair shall be calculated as the sum of all air flows entering the nitric acid production unit.

The operator shall apply the following formula, unless stated otherwise in its monitoring plan:

Vair = Vprim + Vsec + Vseal

Where:

Vprim

Primary input air flow in Nm3/h at standard conditions;

Vsec

Secondary input air flow in Nm3/h at standard conditions;

Vseal

Seal input air flow in Nm3/h at standard conditions.

The operator shall determine Vprim by continuous flow measurement before the mixing with ammonia takes place. The operator shall determine Vsec by continuous flow measurement, including where the measurement is before the heat recovery unit. For Vseal the operator shall consider the purged airflow within the nitric acid production process.

For input air streams accounting for cumulatively less than 2,5 % of the total air flow, the competent authority may accept estimation methods for the determination of that air flow rate proposed by the operator based on industry best practices.

The operator shall provide evidence through measurements under normal operating conditions that the flue gas flow measured is sufficiently homogeneous to allow for the proposed measurement method. Where non-homogeneous flow is confirmed through these measurements, the operator shall take that into account when determining appropriate monitoring methods and when calculating the uncertainty in the N2O emissions.

The operator shall adjust all measurements to a dry gas basis and report them consistently.