xmlns:atom="http://www.w3.org/2005/Atom" xmlns:atom="http://www.w3.org/2005/Atom"

[F1ANNEX VIII U.K. SPECIALISED OPERATIONS [PART-SPO]

SUBPART D INSTRUMENTS, DATA AND EQUIPMENT U.K.

SECTION 2 U.K. Helicopters

SPO.IDE.H.175 Supplemental oxygen — non-pressurised helicopters U.K.
(a) Non-pressurised helicopters operated at flight altitudes when the oxygen supply is required in accordance with (b) shall be equipped with oxygen storage and dispensing apparatus capable of storing and dispensing the required oxygen supplies. U.K.
(b) Non-pressurised helicopters operated above flight altitudes at which the pressure altitude in the cabin compartments is above 10 000 ft shall carry enough breathing oxygen to supply: U.K.
(1)

all crew members for any period in excess of 30 minutes when the pressure altitude in the cabin compartment will be between 10 000 ft and 13 000 ft; and

(2)

all crew members and task specialists for any period that the pressure altitude in the cabin compartment will be above 13 000 ft.

(c) Notwithstanding (b), excursions of a specified duration between 13 000 ft and 16 000 ft may be undertaken without oxygen supplies, -in accordance with SPO.OP.195(b). ]U.K.