Search Legislation

Commission Regulation (EU) No 601/2012 (repealed)Show full title

Commission Regulation (EU) No 601/2012 of 21 June 2012 on the monitoring and reporting of greenhouse gas emissions pursuant to Directive 2003/87/EC of the European Parliament and of the Council (Text with EEA relevance) (repealed)

 Help about what version

What Version

 Help about advanced features

Advanced Features

Close

This is a legislation item that originated from the EU

After exit day there will be three versions of this legislation to consult for different purposes. The legislation.gov.uk version is the version that applies in the UK. The EU Version currently on EUR-lex is the version that currently applies in the EU i.e you may need this if you operate a business in the EU.

The web archive version is the official version of this legislation item as it stood on exit day before being published to legislation.gov.uk and any subsequent UK changes and effects applied. The web archive also captured associated case law and other language formats from EUR-Lex.

Changes to legislation:

There are currently no known outstanding effects for the Commission Regulation (EU) No 601/2012 (repealed), SECTION 1 . Help about Changes to Legislation

Close

Changes to Legislation

Revised legislation carried on this site may not be fully up to date. At the current time any known changes or effects made by subsequent legislation have been applied to the text of the legislation you are viewing by the editorial team. Please see ‘Frequently Asked Questions’ for details regarding the timescales for which new effects are identified and recorded on this site.

SECTION 1 U.K. General provisions

Article 19U.K.Categorisation of installations and source streams

1.Each operator shall determine the category of its installation pursuant to paragraph 2, and, where relevant, of each source stream pursuant to paragraph 3 for the purpose of monitoring emissions and determining the minimum requirements for tiers.

2.The operator shall classify each installation in one of the following categories:

(a)a category A installation, where average verified annual emissions of the trading period immediately preceding the current trading period, with the exclusion of CO2 stemming from biomass and before subtraction of transferred CO2, are equal to or less than 50 000 tonnes of CO2(e);

(b)a category B installation, where the average verified annual emissions of the trading period immediately preceding the current trading period, with the exclusion of CO2 stemming from biomass and before subtraction of transferred CO2, are more than 50 000 tonnes of CO2(e) and equal to or less than 500 000 tonnes of CO2(e);

(c)a category C installation, where the average verified annual emissions of the trading period immediately preceding the current trading period, with the exclusion of CO2 stemming from biomass and before subtraction of transferred CO2, are more than 500 000 tonnes of CO2(e).

3.The operator shall classify each source stream, comparing the source stream against the sum of all absolute values of fossil CO2 and CO2(e) corresponding to all source streams included in calculation-based methodologies and of all emissions of emission sources monitored using measurement-based methodologies, before subtraction of transferred CO2, in one of the following categories:

(a)minor source streams, where the source streams selected by the operator jointly correspond to less than 5 000 tonnes of fossil CO2 per year or to less than 10 %, up to a total maximum contribution of 100 000 tonnes of fossil CO2 per year, whichever is the highest in terms of absolute value;

(b)de-minimis source streams, where the source streams selected by the operator jointly correspond to less than 1 000 tonnes of fossil CO2 per year or to less than 2 %, up to a total maximum contribution of 20 000 tonnes of fossil CO2 per year, whichever is the highest in terms of absolute value;

(c)major source streams, where the source streams do not classify in any category referred to in points (a) and (b).

4.Where the average annual verified emissions of the trading period immediately preceding the current trading period for the installation are not available or inaccurate, the operator shall use a conservative estimate of annual average emissions, with the exclusion of CO2 stemming from biomass and before subtraction of transferred CO2, to determine the category of the installation.

Article 20U.K.Monitoring boundaries

1.An operator shall define the monitoring boundaries for each installation.

Within those boundaries, the operator shall include all relevant greenhouse gas emissions from all emission sources and source streams belonging to activities carried out at the installation and listed in Annex I to Directive 2003/87/EC, as well as from activities and greenhouse gases included by a Member State pursuant to Article 24 of Directive 2003/87/EC.

The operator shall also include emissions from regular operations and abnormal events including start-up and shut-down and emergency situations over the reporting period, with the exception of emissions from mobile machinery for transportation purposes.

2.When defining the monitoring and reporting process, the operator shall include the sector specific requirements laid down in Annex IV.

3.Where leakages from a storage complex pursuant to Directive 2009/31/EC are identified and lead to emissions, or release of CO2 to the water column, they shall be considered as emission sources for the respective installation and shall be monitored in accordance with section 23 of Annex IV to this Regulation.

The competent authority may allow the exclusion of a leakage emission source from the monitoring and reporting process, once corrective measures pursuant to Article 16 of Directive 2009/31/EC have been taken and emissions or release into the water column from that leakage can no longer be detected.

Article 21U.K.Choice of the monitoring methodology

1.For the monitoring of the emissions of an installation, the operator shall choose to apply either a calculation-based methodology or a measurement-based methodology, subject to specific provisions of this Regulation.

A calculation-based methodology shall consist in determining emissions from source streams based on activity data obtained by means of measurement systems and additional parameters from laboratory analyses or default values. The calculation-based methodology may be implemented through the standard methodology set out in Article 24 or the mass balance methodology set out in Article 25.

A measurement-based methodology shall consist in determining emissions from emission sources by means of continuous measurement of the concentration of the relevant greenhouse gas in the flue gas and of the flue gas flow, including the monitoring of CO2 transfers between installations where the CO2 concentration and the flow of the transferred gas are measured.

Where the calculation-based methodology is applied, the operator shall for each source stream define, in the monitoring plan, whether the standard methodology or the mass balance methodology is used, including the relevant tiers in accordance with Annex II.

2.An operator may combine, subject to approval by the competent authority, standard methodology, mass balance and measurement-based methodologies for different emission sources and source streams belonging to one installation, provided that neither gaps nor double counting concerning emissions occur.

3.Where the operator does not choose a measurement-based methodology, the operator shall choose the methodology required by the relevant section of Annex IV, unless he provides evidence to the competent authorities that the use of such methodology is technically not feasible or incurs unreasonable costs, or that another methodology leads to a higher overall accuracy of emissions data.

Article 22U.K.Monitoring methodology not based on tiers

By way of derogation from Article 21(1), the operator may use a monitoring methodology that is not based on tiers (hereinafter ‘the fall-back methodology’) for selected source streams or emission sources, provided that all of the following conditions are met:

(a)

applying at least tier 1 under the calculation-based methodology for one or more major source streams or minor source streams and a measurement-based methodology for at least one emission source related to the same source streams is technically not feasible or would incur unreasonable costs;

(b)

the operator assesses and quantifies each year the uncertainties of all parameters used for the determination of the annual emissions in accordance with the ISO Guide to the Expression of Uncertainty in Measurement (JCGM 100:2008), or another equivalent internationally accepted standard, and includes the results in the annual emissions report;

(c)

the operator demonstrates to the satisfaction of the competent authority that by applying such a fall-back monitoring methodology, the overall uncertainty thresholds for the annual level of greenhouse gas emissions for the whole installation do not exceed 7,5 % for category A installations, 5,0 % for category B installations and 2,5 % for category C installations.

Article 23U.K.Temporary changes to the monitoring methodology

1.Where it is for technical reasons temporarily not feasible to apply the tier in the monitoring plan for the activity data or each calculation factor of a fuel or material stream as approved by the competent authority, the operator concerned shall apply the highest achievable tier until the conditions for application of the tier approved in the monitoring plan have been restored.

The operator shall take all necessary measures to allow the prompt restoration of the tier in the monitoring plan as approved by the competent authority.

2.The operator concerned shall notify the temporary change referred to in paragraph 1 to the monitoring methodology without undue delay to the competent authority, specifying:

(a)the reasons for the deviation from the tier;

(b)in detail the interim monitoring methodology that the operator uses to determine the emissions until the conditions for the application of the tier in the monitoring plan have been restored;

(c)the measures the operator is taking to restore the conditions for the application of the tier in the monitoring plan approved by the competent authority;

(d)the anticipated point in time when application of the tier as approved by the competent authority will be resumed.

Back to top

Options/Help

Print Options

You have chosen to open the Whole Regulation

The Whole Regulation you have selected contains over 200 provisions and might take some time to download. You may also experience some issues with your browser, such as an alert box that a script is taking a long time to run.

Would you like to continue?

You have chosen to open Schedules only

The Schedules you have selected contains over 200 provisions and might take some time to download. You may also experience some issues with your browser, such as an alert box that a script is taking a long time to run.

Would you like to continue?

Close

Legislation is available in different versions:

Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.

Original (As adopted by EU): The original version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.

Close

See additional information alongside the content

Geographical Extent: Indicates the geographical area that this provision applies to. For further information see ‘Frequently Asked Questions’.

Show Timeline of Changes: See how this legislation has or could change over time. Turning this feature on will show extra navigation options to go to these specific points in time. Return to the latest available version by using the controls above in the What Version box.

Close

Opening Options

Different options to open legislation in order to view more content on screen at once

Close

More Resources

Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as adopted version that was used for the EU Official Journal
  • lists of changes made by and/or affecting this legislation item
  • all formats of all associated documents
  • correction slips
  • links to related legislation and further information resources
Close

Timeline of Changes

This timeline shows the different versions taken from EUR-Lex before exit day and during the implementation period as well as any subsequent versions created after the implementation period as a result of changes made by UK legislation.

The dates for the EU versions are taken from the document dates on EUR-Lex and may not always coincide with when the changes came into force for the document.

For any versions created after the implementation period as a result of changes made by UK legislation the date will coincide with the earliest date on which the change (e.g an insertion, a repeal or a substitution) that was applied came into force. For further information see our guide to revised legislation on Understanding Legislation.

Close

More Resources

Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as adopted version that was used for the print copy
  • correction slips

Click 'View More' or select 'More Resources' tab for additional information including:

  • lists of changes made by and/or affecting this legislation item
  • confers power and blanket amendment details
  • all formats of all associated documents
  • links to related legislation and further information resources